久久亚洲精品国产精品777777-久久亚洲精品国产亚洲老地址-久久亚洲精品玖玖玖玖-久久亚洲精品人成综合网-亚洲视频免费在线播放-亚洲视频免费在线观看

您好,歡迎來到中國企業庫   [請登陸]  [免費注冊]
小程序  
APP  
微信公眾號  
手機版  
 [ 免責聲明 ]     [ 舉報 ]
客服電話:13631151688
企業庫首頁>資訊
行業
超級獵聘人才網 廣告

How long can the fire emergency light be used?

作者:Zhizhuo Optoelectronics Technology Co.,Ltd 來源:gdzhizhuo 發布時間:2020-04-29 瀏覽:986
How long can the fire emergency light be used?

    Fire emergency lighting with accumulator should be started at the same time of power failure. The switching time driven by fire emergency power should be within 5 seconds. For emergency lighting for evacuation, the minimum illumination of the ground shall not be lower than 0.5 lx. Emergency lighting and evacuation indicator signs can be used as backup power supply, and the continuous power supply time should not be less than 20min; The continuous power supply time of high-rise buildings with height over 100m should not be less than 30min.

According to the production standard of fire emergency lamp:


    the time of the system shall not be less than 90min and shall not be less than the nominal emergency working time of the lamp]

    GB 50016 -- code for fire protection in architectural design GB 50016 -- code for fire protection in architectural design GB 50016 -- code for fire protection in architectural design

    "Code for fire protection design of high-rise civil buildings" GB 50045-95 (2005 edition) 9.2.6 emergency lighting and evacuation indicator signs, can use battery as backup power, and the continuous power supply time should not be less than 20min; The continuous power supply time for high-rise buildings over 1OOm should not be less than 30min];


    Here refers to the application of fire emergency lights in the building design fire code, the construction engineering design unit with reference to the application of the fire emergency lights minimum emergency time;

    Fire evacuation indicator signs and fire emergency lighting fixtures installed in buildings in accordance with GB 50016 -- 11.3.6 of 2006 shall not only comply with the provisions of this code, but also comply with the relevant provisions of the current national standards fire safety signs GB 13495 and fire emergency lighting GB 17945.

鄭重聲明:資訊 【How long can the fire emergency light be used?】由 Zhizhuo Optoelectronics Technology Co.,Ltd 發布,版權歸原作者及其所在單位,其原創性以及文中陳述文字和內容未經(企業庫www.zgmflm.cn)證實,請讀者僅作參考,并請自行核實相關內容。若本文有侵犯到您的版權, 請你提供相關證明及申請并與我們聯系(qiyeku # qq.com)或【在線投訴】,我們審核后將會盡快處理。
會員咨詢QQ群:902340051 入群驗證:企業庫會員咨詢.
免費注冊只需30秒,立刻尊享
免費開通旗艦型網絡商鋪
免費發布無限量供求信息
每天查看30萬求購信息